§ 01 Sections
All 12 entries.
Sorted by section number. Click any row for the full entry — answer, requirements, edition diff, related sections.
Section
Title
Question
G2401.1
Does the Fuel Gas Code Treat Propane Differently Than Natural Gas? (IRC 2018)
G2401.1
Does the fuel gas code treat propane differently than natural gas?
Does the fuel gas code treat propane differently than natural gas?
→
G2411.1
Does CSST Gas Piping Need to Be Bonded? (IRC 2018)
G2411.1
Does CSST gas piping need to be bonded, and where does the bonding wire attach?
Does CSST gas piping need to be bonded, and where does the bonding wire attach?
→
G2413.1
How Do I Know What Size Gas Line I Need? (IRC 2018)
G2413.1
How do I know what size gas line I need for a furnace, range, tankless water heater, or generator?
How do I know what size gas line I need for a furnace, range, tankless water heater, or generator?
→
G2414.1
What Kind of Gas Pipe Is Allowed in a House Under IRC 2018?
G2414.1
What kind of gas pipe is allowed in a house under IRC 2018?
What kind of gas pipe is allowed in a house under IRC 2018?
→
G2415.12
How Deep Does a Buried Gas Line Need to Be? (IRC 2018)
G2415.12
How deep does a buried gas line need to be, and can plastic gas pipe go under a slab or into the house?
How deep does a buried gas line need to be, and can plastic gas pipe go under a slab or into the house?
→
G2417.1
What Pressure Test Is Required After Installing or Changing a Gas Line? (IRC 2018)
G2417.1
What pressure test is required after installing or changing a gas line?
What pressure test is required after installing or changing a gas line?
→
G2420.5
Where Does the Gas Shutoff Valve Have to Be for a Furnace, Range, Fireplace, Dryer, or Water Heater? (IRC 2018)
G2420.5
Where does the gas shutoff valve have to be for a furnace, range, fireplace, dryer, or water heater?
Where does the gas shutoff valve have to be for a furnace, range, fireplace, dryer, or water heater?
→
G2420.5.1
Can the Gas Shutoff Valve for a Fireplace Be Inside the Fireplace, Behind the Logs, or in the Wall? (IRC 2018)
G2420.5.1
Can the gas shutoff valve for a fireplace be inside the fireplace, behind the logs, or in the wall?
Can the gas shutoff valve for a fireplace be inside the fireplace, behind the logs, or in the wall?
→
G2422.1
Can I Connect a Portable or Standby Generator to My Natural Gas Line? (IRC 2018)
G2422.1
Can I connect a portable or standby generator to my natural gas line with a quick-connect hose?
Can I connect a portable or standby generator to my natural gas line with a quick-connect hose?
→
G2422.1
What Does Code Require for a Natural Gas or Propane Line to an Outdoor Grill? (IRC 2018)
G2422.1
What does code require for a natural gas or propane line to an outdoor grill?
What does code require for a natural gas or propane line to an outdoor grill?
→
G2422.1
What Is the Code-Compliant Way to Hook Up a Gas Dryer? (IRC 2018)
G2422.1
What is the code-compliant way to hook up a gas dryer?
What is the code-compliant way to hook up a gas dryer?
→
G2422.1.2
Can a Flexible Gas Connector Go Through a Wall, Floor, Cabinet, or Furnace Cabinet? (IRC 2018)
G2422.1.2
Can a flexible gas connector go through a wall, floor, cabinet, or furnace cabinet?
Can a flexible gas connector go through a wall, floor, cabinet, or furnace cabinet?
→