jaspector
§ Chapter 3 IRC 2018

Building Planning

22 entries from Chapter 3 of IRC 2018, organized by section number. Each entry covers what the code requires, why it exists, what inspectors look for, and common mistakes.

§ 01   Sections

All 22 entries.

Sorted by section number. Click any row for the full entry — answer, requirements, edition diff, related sections.

What Plumbing Fixtures Are Required in a Dwelling Unit — IRC 2018 P2701.1
P2701.1
What plumbing fixtures are required for a dwelling unit?
→
Fire Separation Distance to Property Line — IRC 2018 R302.1
R302.1
How close can I build a house, addition, deck, or shed to the property line before I need fire-rated walls or protected openings?
→
Garage-to-House Door Requirements Under IRC 2018
R302.5.1
Does the door from the garage into the house have to be fire-rated, solid core, and self-closing?
→
Garage-to-House Fire Separation and Drywall Requirements — IRC 2018
R302.6
Does the wall between my garage and house need to be fire-rated, and what drywall is required?
→
Windows, Natural Light, and Ventilation in Habitable Rooms — IRC 2018 R303.1
R303.1
Do bedrooms and living rooms need windows, or can mechanical ventilation satisfy the code?
→
Bathroom Window or Exhaust Fan Requirement — IRC 2018 R303.3
R303.3
Does a bathroom need an operable window if it has an exhaust fan?
→
Minimum Bedroom and Habitable Room Size — IRC 2018 R304.1
R304.1
What is the minimum size for a bedroom or habitable room?
→
Minimum Ceiling Height for a Finished Basement or Bedroom — IRC 2018 R305.1
R305.1
What is the minimum ceiling height for a basement bedroom or finished basement?
→
Sloped Ceiling Minimum Height in Finished Attic or Bonus Room — IRC 2018 R305.1.1
R305.1.1
How much low or sloped ceiling area is allowed in a finished attic, loft, or bonus room?
→
When Is Tempered or Safety Glass Required Near Doors, Stairs, and Showers — IRC 2018 R308.4
R308.4
When does glass near a door, stair, shower, tub, or floor have to be tempered or safety glass?
→
Does Every Bedroom Need an Egress Window Under IRC 2018?
R310.1
Does every bedroom need an egress window or exterior door?
→
Egress Window Minimum Size, Clear Opening, and Sill Height — IRC 2018
R310.2
What are the minimum egress window size, clear opening, sill height, and dimensions?
→
Required Exterior Egress Door from a House — IRC 2018 R311.2
R311.2
How many exterior doors are required from a house, and does a patio door count?
→
Is a Landing Required at an Exterior Door Under IRC 2018 R311.3?
R311.3
Is a landing required at an exterior door, garage door, or door at the top of stairs?
→
Stairway Tread, Riser, and Handrail Requirements — IRC 2018 R311.7
R311.7
What stairway details does the IRC require beyond basic guard height?
→
When Is a Guardrail Required on a Deck, Porch, or Balcony — IRC 2018
R312.1
When is a guardrail required on a deck, porch, balcony, or stair landing?
→
Guard Height and Maximum Baluster Spacing — IRC 2018 R312.1.3
R312.1.3
How high do guards need to be, and what is the maximum baluster spacing?
→
Where Are Smoke Alarms Required in a House Under IRC 2018?
R314.3
Where are smoke alarms required in a house, bedroom, hallway, basement, or each story?
→
Hardwired and Interconnected Smoke Alarms in Remodels — IRC 2018 R314.4
R314.4
Do smoke alarms have to be hardwired and interconnected when remodeling or finishing a basement?
→
When Are Carbon Monoxide Alarms Required Under IRC 2018?
R315.1
When are carbon monoxide alarms required because of an attached garage, fireplace, furnace, water heater, or gas appliance?
→
Are Single-Family Homes Required to Be Accessible Under IRC 2018 R320?
R320.1
Do new single-family homes or townhouses have to be accessible or adaptable?
→
Pool Fence and Barrier Requirements for Residential Swimming Pools — IRC 2018 R326
R326.1
What fence or barrier is required around a residential swimming pool?
→